PRP Direct is an Emcyte distributor. We have a commercial interest in the systems on this page. That is exactly why every specification here is quoted from the manufacturer's own published documentation and named at the point of use, so you can check it against the source rather than take our word for it.

Where a manufacturer does not publish a figure, we say so instead of estimating. We have not independently tested any device referenced here, and no figure on this page is our own measurement.

Buyer's guide

Compare Emcyte PRP systems

Every Emcyte PRP system concentrates platelets from the patient's own blood. They differ in how many devices the workflow uses, the platelet concentration they are built to reach, and the kit volumes available. This page lays the options side by side so you can match a system to how your practice actually runs, then get itemized pricing.

Figures below are manufacturer-reported device specifications, not claims of clinical efficacy of the prepared PRP.

Platelet-rich plasma systems

SystemWorkflowDisposablesKit volumesBuilt for
PurePRP SPDouble spinOne integrated device, single counterbalance30 / 60 / 120 ccSupraphysiologic platelet concentration with fewer transfer steps
Pure Two PRPDouble spinTwo disposables, established two-step workflow30 / 60 / 120 ccComparable platelet counts on a familiar two-device process
PurePRP (standard)Double spinTwo disposables30 / 60 / 120 ccThe value tier for practices standardizing on a straightforward PRP prep

PurePRP SP is manufacturer-reported to deliver up to roughly 9 billion platelets in a 7 mL dose (GS60) with under 1% red blood cells. Concentration in practice depends on the patient draw and protocol.

Three questions that decide the system

Single vs double spin

A single-spin process separates blood in one centrifugation step and is fast to run. A double-spin process adds a second step to further concentrate the platelet fraction. Every Emcyte PRP system above is double-spin; the single-spin option in the line is AbsolutePRP Gold.

Leukocyte-rich vs leukocyte-poor

Some protocols call for a leukocyte-rich preparation, others for leukocyte-poor. The choice is physician-directed by application; ask about the neutrophil handling for the volume you plan to run.

Kit volume by intent

Kits come in 30, 60, and 120 cc. Smaller volumes suit focal, single-site work; larger volumes suit multi-site or higher-volume final preparations. Match the volume to your typical case, not the maximum.

The rest of the point-of-care line

SystemPreparesNotes
PureBMC SPBone marrow concentrateOne integrated concentrating device, single counterbalance
Pure Two BMCBone marrow concentrateTwo-device kit on an established two-step workflow
ProgenikineAdipose concentrateClosed, single-device; prepares in under 5 minutes
CORE / A2MAlpha-2-macroglobulin concentrateInvestigational-use ultrafiltration component; runs from PurePRP plasma
SuperShotExtracellular-vesicle add-onOne-minute add-on spin; autologous, same regulatory class as standard PRP

One centrifuge runs all of it

The Sapphire Series is a single programmable centrifuge that runs PRP, bone marrow, and adipose presets from a touchscreen, in a 31 lb portable footprint. You do not buy a separate machine per biologic. Loaner and trade-in programs are available.

Get itemized pricing for your practice

Tell us what you run and how many cases a month. A U.S.-based specialist sends a recommended configuration and pricing within one business day.

Request a quote

PRP Direct distributes 510(k)-cleared autologous blood-processing devices. Device specifications are manufacturer-reported and are not claims of clinical efficacy of the prepared biologic. This page is general education for clinicians evaluating equipment and is not medical advice.

What these devices are cleared for

Emcyte's instructions for use define the labeled indication for the PurePRP Supraphysiologic Concentrating System as follows, quoted verbatim:

"The PurePRP® Supraphysiologic Concentrating System is designed to be used for the safe and rapid preparation of autologous platelet rich plasma (PRP) from a small sample of blood at the patient's point of care. The PRP is mixed with autograft and allograft bone prior to application to an orthopedic site to improve bone graft handling characteristics."

The same document states: "The PRP prepared by this device has not been evaluated for any clinical indications." It also states that the safety and effectiveness of the device for in vivo indications such as bone healing and hemostasis have not been established, and that the PRP prepared by the device is not indicated for delivery to the patient's circulatory system.

Any application other than the labeled indication falls outside it. That is not unusual in this field, and it is not something PRP Direct can authorize, recommend, or direct. It rests on the independent clinical judgment of a licensed physician, exercised under their own license and their own informed-consent process. We sell equipment and publish what the manufacturer publishes about it. We do not advise on clinical application.

PRP Direct is a distributor of Emcyte point-of-care blood-processing devices. Emcyte states these systems are 510(k)-cleared as blood-processing devices; clearance covers how a device processes blood, it is not a clearance of the prepared PRP to treat any condition, and no PRP therapy is FDA-approved for a specific indication. Manufacturer specifications are reproduced as the manufacturer's statements, have not been independently verified by PRP Direct, and are not claims of clinical efficacy. Manufacturers revise specifications without notice, and the instructions for use packaged with your kit supersede anything published here. Nothing on this page is dosing, protocol, clinical, or medical advice, and nothing here should be relied upon in making a clinical decision. Product names and trademarks belong to their respective owners.